What Are Excitation Systems?
It provides the power needed to energize the rotor field windings and controls the output voltage of the generator. Without an adequate field current being supplied by the excitation system, a generator would not be able to produce power.
Excitation System Components
An excitation system consists of several main components that work together to regulate the generator’s output voltage.
Field Power Supply
The field power supply provides the DC electric current needed to energize the rotor field windings. Excitation Systems In older systems, a brushless exciter generated this current. Modern systems use a static exciter rectifier that converts the AC output of a small rotating exciter into DC.
Voltage Regulator
The voltage regulator monitors and controls the output of the field power supply. It adjusts the field current as needed to maintain the generator terminal voltage within its specified limits, despite fluctuations in load or generator reactance. Early regulators were manual-control devices, but now microprocessor-based controllers are common.
Sensing and Feedback
Voltage and current transformers located at the generator terminals provide feedback signals to the voltage regulator, allowing it to compare the actual generator voltage to the target setpoint. This closed-loop control system allows very precise voltage regulation.
Protective Devices
Circuit breakers, fuses and other devices protect the excitation system components from damage due to electrical faults or extreme overloads. Some protective relays also monitor for excitation system malfunctions and shut down the generator if needed to prevent more serious issues.
Operating Characteristics of Excitation Systems
Proper excitation is essential for reliable generator operation. Here are some key points about how these systems function:
Field Current Control
By increasing or decreasing the amount of current flowing through the generator rotor field windings, the voltage regulator can raise or lower the terminal voltage as required. More current produced higher terminal voltages.
Response Time
Modern static exciters can respond and adjust the field current very rapidly, within a fraction of a second, allowing them to precisely regulate voltage even during large transient loads. Older brushless designs responded more slowly.
Power Limitations
The field power supply has finite capacity to source current to the rotor windings. Overloading it for too long can damage system components. Protective devices prevent this.
Component Redundancy
Critical excitation system elements like the voltage regulator often have redundant backups to maintain voltage control if the primary component fails. This ensures generator availability.
Failure Modes
Malfunctions can include faulty regulators, shorted windings, broken wires and more. Proper maintenance and condition monitoring helps identify problems early to prevent generator trips.
Impact of Excitation System Performance
Given its vital role in determining terminal voltage and thus generator output power levels, the excitation system’s reliability and dynamic characteristics directly impact overall plant performance. Issues such as:
Disturbance Ride-Through
A fast-responding static exciter allows the generator to ride through minor grid disturbances without tripping. This maintains power supply stability.
Automatic Voltage Regulation
Tight voltage control synchronizes generator output with utility needs and power system requirements like voltage profile along transmission lines.
Transient Stability
Quick field current adjustment stabilizes the generator during large load swings to prevent potential loss of synchronism.
Power Quality
Precise isochronous voltage regulation minimizes disturbances and fluctuations seen by customers downstream.
Equipment Stress
Extended operation at improper voltage levels or transient overvoltages/undervoltages can damage the generator, transformers and other devices over time if not regulated properly.
Excitation systems play a vital yet sometimes overlooked role in electric power generation and delivery. Their control characteristics directly determine power quality, grid reliability and equipment life. Continuous improvement and condition monitoring helps maximize excitation system performance and availability.
*Note:
1.Source: Coherent Market Insights, Public sources, Desk research
2.We have leveraged AI tools to mine information and compile it
About Author:
Ravina Pandya, Content Writer, has a strong foothold in the market research industry. She specializes in writing well-researched articles from different industries, including food and beverages, information and technology, healthcare, chemical and materials, etc. (https://www.linkedin.com/in/ravina-pandya-1a3984191)